The InterSeA research group designed an automated SML sampler, assuring a convenient sampling process, permitting high sample volumes within a reasonable time scale, allowing for research in broad and numerous sites.
The principles of the SML sampler design are based on the significant
a) restriction of sampling duration (less than 1 h),
b) labor restriction of the personnel participating in the SML sampling process and
c) volume increase of SML samples collected.
The automated and easily applicable sampler is designed in order to assure representative collection of an adequate amount of SML sample, of thicknesses less than 60 μm, within a reasonable time scale and minimizing potential contamination of the samples.